Configuration editor
The configuration editor creates the .cfg file used by and . Configure the tools you want, choose the modules used for ECU Data, and create your pages with measurements.
You can interact with the examples below, to learn how to use the editor. You can press their Reset button to undo your changes.
Open an existing configuration
By default, the editor is empty. To return to this state, you can reload the webpage. Please note that you will lose your changes, so download the configuration first.
If you already have a .cfg file you wish to edit, choose Upload file in the editor's top bar and select it.
Step 1: Select tools
Here, you can choose what will appear in your menu.
Tick the checkbox on a tool to enable it. Its settings will appear underneath.
The tools have their own separate Protocol and Module selectors. They do not need to be added to the module lists in Step 2.
Acceleration timer
Select the module and measurement that will provide the vehicle speed, in km/h.
With KWP, enter its Block and Index.
With UDS, choose Direct or From file and complete the source definition as described under UDS sources.
For a UDS Direct source, you can also edit the linear conversion parameters, in case the measurement value needs to be converted.
Oil level
Choose the Protocol and Module, then configure the level (mm) and temperature (°C) source from that module. The two measurement values have separate sources, but they must come from the same module.
Set the minimum and maximum level to the correct limits for your engine. They define the gauge's range.
Engine mileage
Choose the Protocol and Module, then configure the mileage (km) source from that module.
Set the offset to the distance you want subtracted from the current mileage, to obtain the engine mileage. For example, if the car had the engine changed at 50.000km, use offset 50000 to make it show up as 0km in the tool. It will count up from there.
Step 2: Select modules for ECU Data
Add the control modules whose measurements you want to use in . The KWP and UDS lists each allow up to 5 modules. The module addresses, in square brackets, correspond to the usual addresses you see in diagnostic apps.
The order in which the modules are defined does not matter.
If a module is selected in the KWP list, the same module cannot be selected in UDS too (or vice-versa).
If a module is selected as the source for one or more measurements, you will be asked for confirmation if you try to change or remove it. If you confirm, those measurements will be reset and you will need to select another source for them.
Step 3: Add pages and measurements
Pages
Use the Add page button to insert a page at the end.
Deleting a page asks for confirmation. If you confirm, all its measurements will be deleted. It is not possible to undo this operation.
Each page has two display options:
- Aligned units: for the CAN display protocol, this makes it so the measurement units will start at the same horizontal position, instead of being aligned individually to the right side of the screen:
- Bar at bottom: moves the title/page counter/connection indicator bar to the bottom of the screen:

Measurements
Each new page starts with one empty measurement. Press Add measurement to add another, up to 5 per page.
Deleting a measurement asks for confirmation. It is not possible to undo this operation.
Label and unit
The Label (optional) represents the name of the measurement. The text you write in Unit (optional) is displayed next to the value.
The button on the right side of the Unit field lets you insert a few special characters. You can also type/paste them directly.
Source
Choose the source from which the measurement value will be obtained.
You cannot download the configuration if any measurement has an undefined source.
Onboard thermocouple
Use this source to read the temperature from a Type-K thermocouple connected to the onboard screw terminal block.
Please contact us if you need help with this.
KWP source
Select the module, then enter the Block (1–254) and Index (1–4). Block identifies a measuring block, and Index selects one of its four values. You can use the menu to find these parameters.
UDS source: Direct
Select a UDS module and set DEFINITION to Direct if you want to specify the decoding parameters manually.
| Field | Meaning |
|---|---|
| DID | The data identifier to be requested through UDS service 22, written as four hexadecimal characters (big-endian) |
| BYTE POSITION | The index of the byte of the response at which the measurement value starts (0-65535); usually 0 |
| BIT POSITION | The index of the bit inside the first used byte of the response at which the measurement value starts (0-7); usually 0 |
| BIT LENGTH | The number of bits to use from the response: 1–64 for integers, and 32 or 64 for real numbers |
| DATA TYPE | Unsigned integer (only positive numbers) / Signed integer (positive/negative numbers in two's complement encoding) / Real number (floating-point) |
| Big endian | Selects the byte order for the value; if left unchecked, little-endian order is used |
UDS source: From file
Select a UDS module and set DEFINITION to From file if you want to use a preset measurement value, instead of specifying the decoding parameters manually.
Select From file when the measurement is described in the module's definition file.
A CDX file must be installed for this module in order to use this feature. Check out UDS module files for more details.
Display method and decimals
The METHOD controls how the measurement's value is represented:
| METHOD | Result |
|---|---|
| None | The default representation is used |
| Raw value | The internal numeric value is used |
| Linear function | The internal numeric value is converted by the function you define |
| Custom text | The internal numeric value is mapped to a custom list of messages |
DECIMALS controls how many digits are shown after the decimal.
If you choose Auto, the most appropriate number of decimals will be used.
Linear function
The conversion is (FACTOR × X + OFFSET) / DIVISOR, where X is the input value.
You can see the resulting formula at the bottom.
MINIMUM and MAXIMUM limit the resulting value.
You can enter -inf or +inf to disable a limit.
For example, if you want to convert a pressure received as mbar to be displayed as bar (you need to divide by 1000):
- set DIVISOR to
1000(or FACTOR to0.001).
If you also want to subtract the atmospheric pressure (~1000mbar):
- set OFFSET to
-1000if you used the DIVISOR, or to-1if you used the FACTOR (pay attention to the order of operations!)
If you want negative numbers to show up as 0:
- set MINIMUM to 0
- leave MAXIMUM as
+inf, so there is no upper limit
Custom text
Press the Add row button to associate a range of values to a custom message.
The order in which you define the rows only matters if the ranges of multiple rows are overlapping. In that case, the first matching row will be selected.
Deleting a row does not ask for confirmation. It is not possible to undo this operation.
The minimum limit is on the left side, the maximum limit is on the right. The limit types you can choose here are also used by Warnings:
| Type | Meaning |
|---|---|
| Infinite | There is no limit on this side |
| Open | The value you write is not included in the range |
| Closed | The value you write is included in the range |
The value that is compared with the range of each row is the internal value of the measurement, not the value you would normally see!
- for UDS, these values almost always differ
- for KWP, they are often the same value, but you should still check
You can find the internal value by first choosing METHOD Raw value, and observing the result.
The example shows how to configure the table if you want the measurement to say "Cold" when the value is less than 80, "Normal" when it's between 80-110 (inclusive), and "Hot" when it's above 110:
Warnings
The WARNING selector chooses the warning mode for this measurement.
Disabled: the feature is deactivatedInside range: the warning is triggered if the value is inside the configured intervalOutside range: the warning is triggered if the value is outside the configured interval
The limit types are explained above.
When configuring warnings for measurements with METHOD Custom text, the value that is compared with the range is the internal value of the measurement.
Check the Custom text section for more details.
If the following example is paired with the previous example, the warning will be activated when the measurement says "Cold" or "Hot", and deactivated when it says "Normal":
When a warning is activated, the measurement's value starts to flash on and off.

Graph
These are the initial settings used when the measurement is selected for use in the menu.
- Minimum and Maximum define the vertical range
- Rate (ms) sets the interval between plotted points
Step 4: Download and install
Press Download file at the bottom of the editor.
If there are problems in your configuration, the editor will show an error so you can correct it.
If everything is OK, a file with the .cfg extension will be downloaded.
You are allowed to rename the configuration file, but don't change the extension.
Follow the Update webpage (Configuration) chapter for instructions on how to install your configuration file.