Configuration editor

The configuration editor creates the .cfg file used by ECU Data and Tools. Configure the tools you want, choose the modules used for ECU Data, and create your pages with measurements.

Interactive examples

You can interact with the examples below, to learn how to use the editor. You can press their Reset button to undo your changes.

Open an existing configuration​

By default, the editor is empty. To return to this state, you can reload the webpage. Please note that you will lose your changes, so download the configuration first.

If you already have a .cfg file you wish to edit, choose Upload file in the editor's top bar and select it.

Step 1: Select tools​

Here, you can choose what will appear in your Tools menu.

Tick the checkbox on a tool to enable it. Its settings will appear underneath.

The tools have their own separate Protocol and Module selectors. They do not need to be added to the module lists in Step 2.

Example
Interactive example loads as you scroll.

Acceleration timer​

Menu: Acceleration

Select the module and measurement that will provide the vehicle speed, in km/h.

With KWP, enter its Block and Index.

With UDS, choose Direct or From file and complete the source definition as described under UDS sources.

For a UDS Direct source, you can also edit the linear conversion parameters, in case the measurement value needs to be converted.

Example
Interactive example loads as you scroll.

Oil level​

Menu: Oil level

Choose the Protocol and Module, then configure the level (mm) and temperature (°C) source from that module. The two measurement values have separate sources, but they must come from the same module.

Set the minimum and maximum level to the correct limits for your engine. They define the gauge's range.

Example
Interactive example loads as you scroll.

Engine mileage​

Menu: Mileage

Choose the Protocol and Module, then configure the mileage (km) source from that module.

Set the offset to the distance you want subtracted from the current mileage, to obtain the engine mileage. For example, if the car had the engine changed at 50.000km, use offset 50000 to make it show up as 0km in the tool. It will count up from there.

Example
Interactive example loads as you scroll.

Step 2: Select modules for ECU Data​

Add the control modules whose measurements you want to use in ECU Data. The KWP and UDS lists each allow up to 5 modules. The module addresses, in square brackets, correspond to the usual addresses you see in diagnostic apps.

Module order

The order in which the modules are defined does not matter.

Example
Interactive example loads as you scroll.
Duplicates

If a module is selected in the KWP list, the same module cannot be selected in UDS too (or vice-versa).

In use

If a module is selected as the source for one or more measurements, you will be asked for confirmation if you try to change or remove it. If you confirm, those measurements will be reset and you will need to select another source for them.

Step 3: Add pages and measurements​

Pages​

Use the Add page button to insert a page at the end.

Order

The order in which you define the pages here will determine their order in ECU Data. You can use the arrow buttons to change the order.

Title

The Page title is optional. If you leave it empty, the page will not have a title in ECU Data.

Deleting

Deleting a page asks for confirmation. If you confirm, all its measurements will be deleted. It is not possible to undo this operation.

Example
Interactive example loads as you scroll.

Each page has two display options:

  • Centered rows: for the BAP display protocol, this makes it so the measurements will be aligned to the center, instead of left-right:
  • Bar at bottom: this has no effect for the BAP display protocol.

Measurements​

Each new page starts with one empty measurement. Press Add measurement to add another, up to 5 per page.

Order

The order in which you define the measurements here will determine their order on the page in ECU Data. You can use the arrow buttons to change the order.

Deleting

Deleting a measurement asks for confirmation. It is not possible to undo this operation.

Example
Interactive example loads as you scroll.
Layout

If a page contains 5 measurements, the layout will look slightly different.

FISPlus

Unfortunately, it is not possible to align those two lines to match the rest. If you need 5 measurements on a page, we recommend using the Centered rows option.

FISPlus
Color

On color displays, this issue appears on the last line.

Label and unit​

The Label (optional) represents the name of the measurement. The text you write in Unit (optional) is displayed next to the value.

Special symbols

The button on the right side of the Unit field lets you insert a few special characters. You can also type/paste them directly.

Source​

Choose the source from which the measurement value will be obtained.

Source

You cannot download the configuration if any measurement has an undefined source.

Onboard thermocouple​

Use this source to read the temperature from a Type-K thermocouple connected to the onboard screw terminal block.

Help

Please contact us if you need help with this.

KWP source​

Select the module, then enter the Block (1–254) and Index (1–4). Block identifies a measuring block, and Index selects one of its four values. You can use the Meas. blocks (KWP) menu to find these parameters.

Example
Interactive example loads as you scroll.

UDS source: Direct​

Select a UDS module and set DEFINITION to Direct if you want to specify the decoding parameters manually.

FieldMeaning
DIDThe data identifier to be requested through UDS service 22, written as four hexadecimal characters (big-endian)
BYTE POSITIONThe index of the byte of the response at which the measurement value starts (0-65535); usually 0
BIT POSITIONThe index of the bit inside the first used byte of the response at which the measurement value starts (0-7); usually 0
BIT LENGTHThe number of bits to use from the response: 1–64 for integers, and 32 or 64 for real numbers
DATA TYPEUnsigned integer (only positive numbers) / Signed integer (positive/negative numbers in two's complement encoding) / Real number (floating-point)
Big endianSelects the byte order for the value; if left unchecked, little-endian order is used
Example
Interactive example loads as you scroll.

UDS source: From file​

Select a UDS module and set DEFINITION to From file if you want to use a preset measurement value, instead of specifying the decoding parameters manually. Select From file when the measurement is described in the module's definition file.

CDX

A CDX file must be installed for this module in order to use this feature. Check out UDS module files for more details.

DID, Key

Use the Path menu to find the values you need to write for DID and Key.

Example
Interactive example loads as you scroll.

Display method and decimals​

The METHOD controls how the measurement's value is represented:

METHODResult
NoneThe default representation is used
Raw valueThe internal numeric value is used
Linear functionThe internal numeric value is converted by the function you define
Custom textThe internal numeric value is mapped to a custom list of messages

DECIMALS controls how many digits are shown after the decimal.

Auto DECIMALS

If you choose Auto, the most appropriate number of decimals will be used.

Linear function​

The conversion is (FACTOR × X + OFFSET) / DIVISOR, where X is the input value. You can see the resulting formula at the bottom.

MINIMUM and MAXIMUM limit the resulting value.

Infinite limits

You can enter -inf or +inf to disable a limit.

For example, if you want to convert a pressure received as mbar to be displayed as bar (you need to divide by 1000):

  • set DIVISOR to 1000 (or FACTOR to 0.001).

If you also want to subtract the atmospheric pressure (~1000mbar):

  • set OFFSET to -1000 if you used the DIVISOR, or to -1 if you used the FACTOR (pay attention to the order of operations!)

If you want negative numbers to show up as 0:

  • set MINIMUM to 0
  • leave MAXIMUM as +inf, so there is no upper limit
Example
Interactive example loads as you scroll.

Custom text​

Press the Add row button to associate a range of values to a custom message.

Order

The order in which you define the rows only matters if the ranges of multiple rows are overlapping. In that case, the first matching row will be selected.

Deleting

Deleting a row does not ask for confirmation. It is not possible to undo this operation.

The minimum limit is on the left side, the maximum limit is on the right. The limit types you can choose here are also used by Warnings:

TypeMeaning
InfiniteThere is no limit on this side
OpenThe value you write is not included in the range
ClosedThe value you write is included in the range
Raw value

The value that is compared with the range of each row is the internal value of the measurement, not the value you would normally see!

  • for UDS, these values almost always differ
  • for KWP, they are often the same value, but you should still check

You can find the internal value by first choosing METHOD Raw value, and observing the result.

The example shows how to configure the table if you want the measurement to say "Cold" when the value is less than 80, "Normal" when it's between 80-110 (inclusive), and "Hot" when it's above 110:

Example
Interactive example loads as you scroll.

Warnings​

The WARNING selector chooses the warning mode for this measurement.

  • Disabled: the feature is deactivated
  • Inside range: the warning is triggered if the value is inside the configured interval
  • Outside range: the warning is triggered if the value is outside the configured interval

The limit types are explained above.

Raw value

When configuring warnings for measurements with METHOD Custom text, the value that is compared with the range is the internal value of the measurement. Check the Custom text section for more details.

If the following example is paired with the previous example, the warning will be activated when the measurement says "Cold" or "Hot", and deactivated when it says "Normal":

Example
Interactive example loads as you scroll.

When a warning is activated, the measurement's row starts to flash on and off.

FISPlus

Graph​

This feature is not supported on BAP clusters.

Step 4: Download and install​

Press Download file at the bottom of the editor.

Errors

If there are problems in your configuration, the editor will show an error so you can correct it.

CFG

If everything is OK, a file with the .cfg extension will be downloaded.

Name

You are allowed to rename the configuration file, but don't change the extension.


Follow the Update webpage (Configuration) chapter for instructions on how to install your configuration file.